Electronic Microcircuits: 7703601DX, 7703-625, 77040
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
7703601DX | 5962-01-119-4698 | Microcircuit, Digital | Inclosure Configuration: Flat pack Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Hermetically sealed and monolithic and positive outputs | DLA Land and Maritime (67268) | |
7703-625 7703625 | 5962-01-170-0313 | Microcircuit, Memory | Inclosure Configuration: Dual-in-line Operating Temp Range: -0.0 to 70.0 deg celsius Features Provided: Electrostatic sensitive and gated output and hermetically sealed and parallel operation and positive outputs and programmable and ultraviolet erasable and W/transparent lid and 3-STATE output | Extel Corp. (52247) | |
7703-626 7703626 | 5962-01-170-0312 | Microcircuit, Memory | Inclosure Configuration: Dual-in-line Operating Temp Range: -0.0 to 70.0 deg celsius Features Provided: Electrostatic sensitive and gated output and hermetically sealed and parallel operation and positive outputs and programmable and ultraviolet erasable and W/transparent lid and 3-STATE output | Extel Corp. (52247) | |
77037 | 5962-01-074-3407 | Microcircuit, Digital | Inclosure Configuration: Dual-in-line Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Hermetically sealed and monolithic and positive outputs and expandable and low power | DLA Land and Maritime (67268) | |
77037 | 5962-01-117-8547 | Microcircuit, Digital | Inclosure Configuration: Flat pack Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Hermetically sealed and monolithic and positive outputs | DLA Land and Maritime (67268) | |
77037 | 5962-01-120-4001 | Microcircuit, Digital | Inclosure Configuration: Dual-in-line Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Burn in and hermetically sealed and monolithic | DLA Land and Maritime (67268) | |
7703701EA | 5962-01-074-3407 | Microcircuit, Digital | Inclosure Configuration: Dual-in-line Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Hermetically sealed and monolithic and positive outputs and expandable and low power | DLA Land and Maritime (67268) | |
7703701EB | 5962-01-074-3407 | Microcircuit, Digital | Inclosure Configuration: Dual-in-line Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Hermetically sealed and monolithic and positive outputs and expandable and low power | Military Specifications (81349) | |
7703701EX | 5962-01-074-3407 | Microcircuit, Digital | Inclosure Configuration: Dual-in-line Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Hermetically sealed and monolithic and positive outputs and expandable and low power | DLA Land and Maritime (16236,67268) Military Specifications (81349) | |
7703701FA | 5962-01-117-8547 | Microcircuit, Digital | Inclosure Configuration: Flat pack Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Hermetically sealed and monolithic and positive outputs | DLA Land and Maritime (67268) | |
7703701FB | 5962-01-117-8547 | Microcircuit, Digital | Inclosure Configuration: Flat pack Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Hermetically sealed and monolithic and positive outputs | DLA Land and Maritime (67268) | |
7703701FC | 5962-01-117-8547 | Microcircuit, Digital | Inclosure Configuration: Flat pack Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Hermetically sealed and monolithic and positive outputs | DLA Land and Maritime (67268) | |
7703701FX | 5962-01-117-8547 | Microcircuit, Digital | Inclosure Configuration: Flat pack Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Hermetically sealed and monolithic and positive outputs | DLA Land and Maritime (67268) | |
7703702EA | 5962-01-120-4001 | Microcircuit, Digital | Inclosure Configuration: Dual-in-line Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Burn in and hermetically sealed and monolithic | DLA Land and Maritime (67268) | |
7703702EA | 5962-01-219-9571 | Microcircuit, Digital | III End Item Identification: Target acquisition designation sight, pilot | DLA Land and Maritime (16236) | |
7703702EB | 5962-01-120-4001 | Microcircuit, Digital | Inclosure Configuration: Dual-in-line Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Burn in and hermetically sealed and monolithic | DLA Land and Maritime (67268) | |
7703702EC | 5962-01-120-4001 | Microcircuit, Digital | Inclosure Configuration: Dual-in-line Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Burn in and hermetically sealed and monolithic | DLA Land and Maritime (67268) | |
7703702EX | 5962-01-120-4001 | Microcircuit, Digital | Inclosure Configuration: Dual-in-line Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Burn in and hermetically sealed and monolithic | DLA Land and Maritime (67268) | |
77039 | 5962-01-252-7942 | Microcircuit, Linear | Inclosure Configuration: CAN Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Hermetically sealed and monolithic and negative outputs and positive outputs | DLA Land and Maritime (67268) | |
7703901GA | 5962-01-252-7942 | Microcircuit, Linear | Inclosure Configuration: CAN Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Hermetically sealed and monolithic and negative outputs and positive outputs | DLA Land and Maritime (67268) | |
7703901GB | 5962-01-252-7942 | Microcircuit, Linear | Inclosure Configuration: CAN Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Hermetically sealed and monolithic and negative outputs and positive outputs | DLA Land and Maritime (67268) | |
7703901GX | 5962-01-252-7942 | Microcircuit, Linear | Inclosure Configuration: CAN Operating Temp Range: -55.0 to 125.0 deg celsius Features Provided: Hermetically sealed and monolithic and negative outputs and positive outputs | DLA Land and Maritime (67268) | |
77040 | 5962-01-100-8948 | Microcircuit, Linear | Inclosure Configuration: CAN Operating Temp Range: -55.0/+150.0 deg celsius Features Provided: Hermetically sealed and monolithic and negative outputs and positive outputs | DLA Land and Maritime (67268) | |
77040 | 5962-01-128-3891 | Microcircuit, Linear | Body Length: 1.439 inches minimum and 1.573 inches maximum Body Width: 0.990 inches minimum and 1.050 inches maximum Body Height: 0.250 inches minimum and 0.450 inches maximum | DLA Land and Maritime (67268) | |
77040 | 5962-01-162-5569 | Microcircuit, Linear | Inclosure Configuration: CAN Operating Temp Range: -55.0/+125.0 deg celsius Features Provided: Hermetically sealed and monolithic and negative outputs and positive outputs | DLA Land and Maritime (67268) | |
77040 | 5962-01-273-0785 | Microcircuit, Linear | Inclosure Configuration: CAN Operating Temp Range: -55.0/+125.0 deg celsius Features Provided: Monolithic and hermetically sealed | DLA Land and Maritime (67268) | |